GBP 1.50 to 2.95 depending on weight.
Postage from GBP 2.00 Europe and 2.50 rest of world.
Your Health
Diabetes
Blood Glucose Meters
GlucoMen Visio Blood Glucose Meter

GlucoMen Visio Blood Glucose Meter
Blood glucose meter for self-testing with memory and PC interface capability
- Painless sampling from the palm and other alternative sites
- Blood glucose measuring starts only when the correct amount of blood has been applied to the strip. This guarantees an accurate result.
- If there is insufficient blood to start the reaction, you can add a second drop directly to the application tip at the end of the strip.
-
When used with the GlucoMen Lancets and Glucoject Dual lancing device:
reduces the discomfort of finger sampling
allows new painless sampling method on alternative sites (AST). - Accurate results in just 10 seconds.
- 250 results are automatically stored with date and time, offering the possibility of taking an average over 14 or 30 days.
- The results can be downloaded to your computer using the Dialogue software.
This system is suitable for self testing
Frequent blood glucose testing is important It tells you how your diabetes is affected by factors such as medication, diet, exercise, and stress management. Blood glucose test results can also tell you if your diabetes is changing in ways that affect your treatment plan.
Always consult your diabetes healthcare professional before making any changes.
All of the information needed to use the GlucoMen Visio meter is included in your manual. Please read it thoroughly before using the system.
If you have any questions, please contact A. Menarini Diagnostics for assistance on:
(UK) 0800 243667 - (Ireland) 1800 709903.
Contact your healthcare professional with questions if you are unable to reach the Menarini Helpline.
Please remember to return the enclosed warranty card.
Intended Use
The GlucoMen Visio Blood Glucose Monitoring System is intended for the quantitative measurement of glucose in fresh whole-capillary blood and fresh whole-venous blood.
Testing is done outside the body (in vitro diagnostic use).
It is intended for blood glucose self-testing at home. It may also be used in clinical settings by healthcare professionals.
Important Information
(1)
A blood glucose level in a normal subject, under fasting conditions, is between 3.8 mmol/L (70 mg/dL) and 6.1 mmol/L (110 mg/dL)
A blood glucose level, under fasting conditions, between 6.1 mmol/L (110 mg/dL) and 6.9 mmol/L (125 mg/dL) is an indication of impaired fasting glucose
A blood glucose level, under fasting conditions, over 7.0 mmol/L (126 mg/dL) is an indicator of diabetes
(1) Report of the expert committee on the diagnosis and classification of diabetes mellitus. Diabetes Care 1999;22:S5- 19
Important
The GlucoMen Visio Sensor is the exclusive test strip for the GlucoMen Visio meter
Before using the GlucoMen Visio meter, read the instructions on the GlucoMen Visio Sensor package insert carefully. Follow all the instructions to ensure safe and accurate operation of the meter.
To perform a blood glucose test, you must draw blood using a lancing device and lancet Please use the Glucoject Dual lancing device and GlucoMen Lancets Fine.
Before using the Glucoject Dual lancing device to obtain blood, read the appropriate instructions carefully
Be very careful when handling these materials, especially when dealing with blood.
Note:
The GlucoMen Visio system does not contain latex by design.
Note:
Healthcare professionals who test their patients blood are advised to wear non latex disposable gloves.
Glucoject Dual and GlucoMen Lancets Fine are products manufactured by Owen Mumford Ltd. Brook Hill, Woodstock, Oxford 0X20 1TU, UK
GlucoMen Visio, for easy self monitoring
The GlucoMen Visio meter is able to measure blood glucose levels using a micro blood sample (only 0.8 µL of blood). This important innovation makes it possible to deal with the pain felt when blood sampling through:
- Alternative site testing (AST) rather than fingertip sampling
- Reducing the blood volume needed when fingertip sampling
Painless Blood sampling in alternative sites
This type of sampling can be considered painless, as skin sensitivity is very low at alternative sites. Therefore, we recommend using GlucoMen Lancets fine, combined with Glucoject Dual lancing device with the clear cap especially designed for AST.
Their combined use comfortably assures you obtain the necessary blood sample volume needed to determine blood glucose values using GlucoMen Visio.
This kind of sampling cannot always be performed, as a rapid increase or decrease in blood glucose levels may lead to incorrect results. For further details please consult the meter manual or the sensor leaflet
Pain reduction in finger sampling
If sampling of alternative sites isn't possible, finger sampling where obvious sensitivity is very high becomes necessary. However in this case, thanks to the reduced blood sample volume required by GlucoMen Visio, combined with the especially designed accessories, the pain due to fingertip sampling is remarkably reduced.
For fingertip sampling we recommend, together with GlucoMen Visio, the use of the GlucoMen Lancets fine combined with Glucoject Dual lancing device.
This will drastically reduce the annoying pain sensation felt when finger sampling. This lancing device incorporates a specific "Comfort Zone" cap for finger sampling with an exclusive "nerve confusing system". It also offers depth and spring force regulation and adjustment.
For safety reasons, use the lancet only once. Be advised that changing the lancet after each blood sample also reduces pain.
Consumables:
- GlucoMen Visio Test Strips are available in boxes of 50. They are available on NHS prescriptions from your GP, or you can buy them by clicking on the link.
- GlucoMen lancets are available in boxes of 100. They are available on NHS prescriptions from your GP, or you can buy them by clicking on the link.
- Batteries are available free of charge from the helpline
- Control solutions can be bought by phoning the helpline
Customer helpline - 0800 243667 (Freephone)
If you have any problems or queries about GlucoMen Visio, then phone the Menarini Diagnostics helpline on Freephone 0800 243667. You can also order free replacement batteries from here, and buy control solutions.
Guarantee
There is a lifetime guarantee on the meter. Phone the helpline on 0800 243667 for details.
Web Site - www.menarinidiag.co.uk
Use Outside the UK: This meter gives readings in mmol/l, which are the standard units used in the UK. Some countries use the US standard of mg/dl and this meter will not be suitable for you to use
VAT Exemption: If you are diabetic and buying this for your own use, then you need not pay VAT for this item. See our VAT Exemption Form for more details
Recycling Information: Old items of electrical equipment should be recycled and not just thrown into the bin. See our Environmental Policy for more details